SCIENCE AND TECHNOLOGY OF CEREALS, OILS AND FOODS

1. Chinese Science Citation Database (CSCD)
2. A Guide to the Core Journals of China (2023)
3. The Key Magazine of China Science and Technology
4. Chinese Applied Core Journals (CACJ)
5. China Core Agricultural and Forestry Journals
6. Bilingual Communication Project for Chinese STM Journals
7. China Fine Periodical Exhibition
8. Elsevier-Scopus Database
9. Directory of Open Access Journals (DOAJ)
10. EBSCO Research Database
11. Chemical Abstracts (CA)
12. Food Science and Technology Abstract (FSTA)
13. CAB International (CABI) Database
14. Japan Science and Technology Agency Chinese Bibliographic Database (JSTChina)
15. Ulrich's Periodicals Directory (UPD)
16. OA Open Access Model Journal

Determination of Chlormequat Residues in Grains and Oils by Gas Chromatography-Tandem Massspectrometry with QuEChERS
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The aim of this study is to develop a method for the determination of chlormequat (CCC) residues in grain and oil. The pretreatment by using QuEChERS and Gas Chromatography-Tandem Massspectrometry (GC-MS/MS) analysis were optimized. The samples were extracted from wheat flour, rice, corn, soybean, soybean oil, rapeseed, and rapeseed oil with acetonitrile and salted out with anhydrous magnesium sulfate, and sodium chloride, then cleaned up by a mixture of N-propyl ethylenediamine (PSA) and octadecyl silane (C18) adsorbents. The matrix effects of different substrates (wheat flour, rice, rapeseed, rapeseed oil) were investigated by derived mass spectrometry and matrix-matched calibration combined with external standards was used for quantitative analysis. The results showed a good linearity in the range of 0.05~2 μg/mL for CCC in different matrixes, with correlation coefficients (R2) of more than 0.9980. The limits of detection (LODs) and the limits of quantification (LOQs) of the method were 0.004~0.009 mg/kg and 0.01~0.03 mg/kg, respectively. The averagerecoveries at three spiked levels were 73.6%~99.1%, and the relative standard deviations (RSDs) were 2.34%~7.78% (n = 6). The method was efficient and sensitive, and satisfied the testing requirements for chlormequat residues in grain and oil samples.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: September 26,2022
  • Published:
Article QR Code